6
COMMERCIALANDINDUSTRIALTEMPERATURERANGES
IDT2308A
3.3V ZERO DELAY CLOCK MULTIPLIER
NOTE:
1. Applies to both REF and FBK.
DC ELECTRICAL CHARACTERISTICS - INDUSTRIAL
Symbol
Parameter
Conditions
Min.
Typ.(1)
Max.
Unit
VIL
InputLOWVoltageLevel
—
0.8
V
VIH
Input HIGH Voltage Level
2
—
V
IIL
InputLOWCurrent
VIN = 0V
—
50
A
IIH
Input HIGH Current
VIN = VDD
—
100
A
VOL
OutputLOWVoltage
IOL = 8mA (-1, -2, -3, -4)
—
0.4
V
IOL = 12mA (-1H, -2H)
VOH
Output HIGH Voltage
IOH = -8mA (-1, -2, -3, -4)
2.4
—
V
IOH = -12mA (-1H, -2H)
IDD_PD
Power Down Current
REF = 0MHz (S2 = S1 = H)
—
25
A
100MHz CLKA (-1, -2, -3, -4)
—
45
100MHz CLKA (-1H, -2H)
—
70
IDD
SupplyCurrent
UnloadedOutputs
66MHz CLKA (-1, -2, -3, -4)
—
32
mA
Select Inputs at VDD or GND
66MHz CLKA (-1H, -2H)
—
50
33MHz CLKA (-1, -2, -3, -4)
—
18
33MHz CLKA (-1H, -2H)
—
30
Symbol
Parameter
Test Conditions
Min.
Max.
Unit
VDD
SupplyVoltage
3
3.6
V
TA
OperatingTemperature(AmbientTemperature)
-40
+85
°C
CL
Load Capacitance below 100MHz
—
30
pF
Load Capacitance from 100MHz to 133MHz
—
15
pF
CIN
InputCapacitance(1)
—7
pF
OPERATINGCONDITIONS-INDUSTRIAL